LDI 160 kN 210 kN - Lant dublu de intindere pentru 400 kV, cu 2 conductoare pe faza
Zona
SMS(kN) |
II / A
160 |
II
210 |
III
160 |
IV
160 |
|
I (mm) |
3414 |
3434 |
3516 |
3642 |
L (mm) |
4764-4924 |
4786-4946 |
4866-5026 |
4992-5152 |
Tip inele |
IPS-9-TT |
IPS-12-TT |
IPS-4-TT |
IPS-8-TT |
de protectie |
IPI-2-TT |
IPI-3-TT |
IPI-6-TT |
IPI-6-TT |
Poz |
Denumire |
Buc |
Material |
Caracteristici Tehnice |
|
1 |
Carlig de tip balama |
2 |
Ol-Zn |
B10/25, 250 kN |
2 |
Piesa de distantare |
2 |
Ol-Zn |
PDf-25/1, 250 kN |
3 |
Furca ochi dreapta |
2 |
Ol-Zn |
FODS-16(21), 160(210) kN |
4 |
Inel de protectie superior |
2 |
Ol-Zn |
IPS |
5 |
Izolator compozit, 400 kV |
2 |
Cauciuc siliconic |
CI-220-II-120/160-TT |
|
|
|
|
CI-220-III-120/160-TT |
|
|
|
|
CI-220-IV-120/160-TT |
6 |
Inel de protectie inferior |
2 |
Ol-Zn |
IPI |
7 |
Furca ochi rasucita |
2 |
Ol-Zn |
FORS-16(21), 160(210) kN |
8 |
Jug dublu |
1 |
Ol-Zn |
Jd 500/400-32, 320 kN |
9 |
Ochi dublu rasucit |
2 |
Ol-Zn |
ODR-20, 200 kN |
10 |
Intinzator reglabil |
2 |
Ol-Zn |
IROF-18, 180 kN |
11 |
Clema de tractiune |
2 |
Ol-Zn |
TPDFc 450/75, 95 % UTS |
Obs: |
|
* Distanta de eclatare k este conforma cu supratensiunile de trasnet si de comutatie stabilite de proiectantul ( beneficiarul ) liniei.
|